Fault messages & troubleshooting
14.7.10 Unit was restarted after power failure
14.7.11 Door is open - cooking program was stopped
112
Troubleshooting
Confirm message. An automatic restore starts.
Next, update the software.
If the error continues to appear, the operating panel needs to be
replaced. With software version 1.78 (10/2018) or higher, a
restore is possible by means of a rescue tool. Contact the
manufacturer in this regard.
Description
The message appears after an interruption of the supply voltage
during an active cooking program.
Troubleshooting
Make sure that the unit was not switched off by means of the "On/
Off" switch during an active cooking program. In this case, the
control is disconnected from power, which is interpreted by the
software as a power failure. Stop the cooking program before
switching the unit off.
Make sure that the customer's supply voltage is reliable.
Check that the "On/Off" switch functions properly and is in the
correct position.
The switch must be fastened securely.
The switch is available separately.
Check the electrical connections and screw connections in the
area of the mains connection terminal, transformer and power line
to the control board (connector X1).
Replace control board. It supplies voltage to the operating panel.
Replace transformer.
Replace operating panel.
Description
During fault-free operation, this message appears if the cooking
chamber door is opened during an active cooking program. If the
message is displayed with a closed cooking chamber door, there is
an error on the reed contact switch or door magnet.
Service instructions