Henny Penny FlexFusion FPE-615 Service Instructions Manual page 77

Electric & gas platinum combi
Hide thumbs Also See for FlexFusion FPE-615:
Table of Contents

Advertisement

Prerequisite Unit dead
DANGER
DANGER
WARNING
Gas shut-off valve on the unit is closed
Left side wall removed
Unscrew the bolts from the gas solenoid valve.
Remove the gas solenoid valve.
Remove the gas orifice with seal.
Risk of asphyxiation and explosion from damaged seals
• Check seals for damage
• Replace damaged seals
• Use only seals that are approved for use with gas
Select the gas orifice specified for the gas type available and install,
together with seal, for place of the existing gas orifice. Replace
damaged seal if necessary.
Replace the supplementary label for gas type on the unit with the
appropriate supplementary label for the gas type available.
Replace the gas solenoid valve and secure it with the bolts.
On models with two burners: Repeat the procedure for the second
burner.
Open the gas shut-off valve on the unit, while paying attention to the
pressure in the gas connection line.
Risk of explosion and fire from escaping gas
• When bleeding air from or degassing the gas system and the unit, ensure
that the air and gas are discharged to the outside in a technically correct
manner and without creating a risk.
Check for leaks outside the unit.
Risk of poisoning from exhaust gases
• Ensure that exhaust gases are discharged properly and that the necessary
amount of combustion air is supplied.
• Ensure that a maximum CO content of < 0.1 vol. % or < 1000 ppm is
achieved in undiluted exhaust gas.
Switch on the unit.
Check for leaks inside the unit.
Make CO
settings.
2
Switch off unit and attach side wall.
Service instructions
Gas technology
77