Offset pressure overview
13.Press the "Stop" button.
The flame extinguishes.
The burner is off.
14.Press the Back button twice.
The main menu appears.
15.Switch off the unit.
Output
Range (mbar)
High
-0.8 — 0
Low
-0.4 — 0
Service instructions
Gas technology
Optimal (mbar)
-0.55
-0.15
81