16.2 Command Examples
This example creates the cluster CManage in VLAN 1. Then, it looks at the current list of candidates for
membership in this cluster and adds two switches to cluster.
sysname# configure
sysname(config)# cluster 1
sysname(config)# cluster name CManage
sysname(config)# exit
sysname# show cluster candidates
Clustering Candidates:
Index Candidates(MAC/HostName/Model)
0 00:13:49:00:00:01/ES-2108PWR/ES-2108PWR
1 00:13:49:00:00:02/GS-3012/GS-3012
2 00:19:cb:00:00:02/ES-3124/ES-3124
sysname# configure
sysname(config)# cluster member 00:13:49:00:00:01 password 1234
sysname(config)# cluster member 00:13:49:00:00:02 password 1234
sysname(config)# exit
sysname# show cluster member
Clustering member status:
Index MACAddr
1 00:13:49:00:00:01 ES-2108PWR
2 00:13:49:00:00:02 GS-3012
The following table describes the labels in this screen.
Table 39 show cluster member
LABEL
Index
MACAddr
Name
Status
Chapter 16 Cluster Commands
Name
DESCRIPTION
This field displays an entry number for each member.
This field displays the member's MAC address.
This field displays the member's system name.
This field displays the current status of the member in the cluster.
Online: The member is accessible.
Error: The member is connected but not accessible. For example, the member's
password has changed, or the member was set as the manager and so left the
member list. This status also appears while the Switch finishes adding a new member to
the cluster.
Offline: The member is disconnected. It takes approximately 1.5 minutes after the link
goes down for this status to appear.