166 en | Troubleshooting transponders, points, receivers, and alert units
Attribute
AlgoNumber
AlarmIcon
TS_TrpID
TS_MUXAddress
Rx_LocationText
MapXPosition
MapYPosition
SensitivityAdjust
BitmapNumber
2017.08 | V2.18.1.0 | DOC
Value
This field should contain only numeric ASCII characters. Valid
values are: 0 (Default), 1 (Classic). 2 (Linear), 3 (Low), 4
(Medium) and 5 (Strong).
Floor level of the point. This field should contain only numeric
ASCII characters. Valid values are: 0 (Basement5), 1 (Basement4),
2 (Basement3), 3 (Basement2), 4 (Basement1), 5 (Tunnel), 6
(Basement), 7 (Ground), 8 (Outside), 9 (Floor 1), 10 (Floor 2), 11
(Floor 3), 12 (Floor 4), 13 (Floor 5), 14 (Floor 6), 15 (Floor 7), 16
(Floor 8), 17 (Floor 9), 18 (Floor 10), 19 (Floor 11), 20 (Floor 12),
21 (Floor 13), 22 (Floor 14), 23 (Floor 15), 24 (Floor 16), 25
(Floor 17), 26 (Floor 18), 27 (Floor 19), 28 (Floor 20), 29 (Floor
21), 30 (Floor 22), 31 (Floor 23), 32 (Floor 24), 33 (Floor 25), 34
(Floor 26), 35 (Floor 27), 36 (Floor 28), 37 (Floor 29), 38 (Floor
30), 39 (Floor 31), 40 (Floor 32), 41 (Floor 33), 42 (Floor 34), 43
(Floor 35), 44 (Floor 36), 45 (Floor 37), 46 (Floor 38), 47 (Floor
39), 48 (Floor 40), 49 (Floor 41), 50 (Floor 42), 51 (Floor 43), 52
(Floor 44), 53 (Floor 45), 54 (Floor 46), 55 (Floor 47), 56 (Floor
48), 57 (Floor 49), 58 (Floor 50), 59 (Floor 51), 60 (Floor 52), 61
(Floor 53), 62 (Floor 54), 63 (Floor 55), 64 (Floor 56), 65 (Floor
57), 66 (Floor 58), 67 (Floor 59), 68 (Floor 60), 69 (Floor 61), 70
(Floor 62), 71 (Floor 63), 72 (Floor 64), 73 (Floor 65), 74 (Floor
66), 75 (Floor 67), 76 (Floor 68), 77 (Floor 69), 78 (Floor 70), 79
(Floor 71), 80 (Floor 72), 81 (Floor 73), 82 (Floor 74), 83 (Floor
75), 84 (Floor 76), 85 (Floor 77), 86 (Floor 78), 87 (Floor 79), 88
(Floor 80), 89 (Floor 81), 90 (Floor 82), 91 (Floor 83), 92 (Floor
84), 93 (Floor 85), 94 (Floor 86), 95 (Floor 87), 96 (Floor 88), 97
(Floor 89), 98 (Floor 90), 99 (Floor 91), 100 (Floor 92), 101
(Floor 93), 102 (Floor 94), 103 (Floor 95), 104 (Floor 96), 105
(Floor 97), 106 (Floor 98), 107 (Floor 99).
This field contains the Transponder ID of the alert unit. If this is
not configured, the value is 0. This field should contain only
numeric ASCII characters.
This field contains the alert unit point number. If this is not
configured, the value is -1. This field should contain only numeric
ASCII characters.
Location of the point. This field may be up to 100 characters. This
field may contain any printable ASCII character except the '?'.
X position of the point on the map. Default value is 0. This field
should contain only numeric ASCII characters.
Y position of the point on the map. Default value is 0. This field
should contain only numeric ASCII characters.
0-99. This field should contain only numeric ASCII characters.
0-99. This field should contain only numeric ASCII characters.
Training Manual
Security Escort