● You know the firmware version of your SINAMICS S120.
● The hardware is completely assembled and wired. For information, refer to
● You provided hardware limit switches and EMERGENCY-OFF switches for safe and
CPU 317TF-3PN/DP: Controlling a SINAMICS S120 with Safety Functions
Getting Started, 10/2013, A5E02982990-04
If you do not know the firmware version, you can find the version listed in the supplied
documents. Alternatively, you can open the "content.txt" file on the CF card. The firmware
version is in the "Internal Version" entry. You can find more detailed information on
reading the firmware version in the SINAMICS S120 product information.
Note
We have used a SINAMICS S120 training case as an example of a drive for this Getting
Started. The training case is available under the following order number:
• 2-axis version with 1FK7 motors
6ZB2480-0CM00
Getting Started CPU 31x: Commissioning
reliable operation of the system. This EMERGENCY-OFF switch is independent of the
emergency stop switch described in the application example.
WARNING
Risk of accident
Non-compliance with the regulations can result in serious injuries and damage to
machines and equipment.
Operation of an S7-300 as part of plants or systems is subject to special rules and
regulations, based on its field of application. Please note the current safety regulations
for the prevention of accidents, e.g. IEC 204 (EMERGENCY-OFF equipment).
.
Preparation
2.1 Requirements