Configuration
4.12 Configuring safety functions on the drive
Step
Activity
4
In the "PROFIsafe address" field, enter the hexadecimal value of the "F target address" of the master-slave
coupling for the drive from HW Config. In this case, the address 1022 (3FE hex) was automatically assigned in
HW Config.
5
Click "Close" to confirm the entries and close the "Configuration" dialog.
6
Click "Safe stop functions" in the "Safety integrated" dialog.
Enter 5 mm in the "Safe stop functions" dialog, "Standstill tolerance SOS" dialog box.
Click "Close" to confirm the entries and close the "Safe stop functions" dialog.
7
Click "Safe limited speed (SLS)" in the "Safety integrated" dialog.
70
CPU 317TF-3PN/DP: Controlling a SINAMICS S120 with Safety Functions
Getting Started, 10/2013, A5E02982990-04