Configuration
4.3 Configuring the F-DI signal module
Step
Activity
9
Open the "Supply module 1VS / 3VS" folder. Assign the parameters of the channels used as shown in the
"Configuration of the input channels" table:
Keep the default settings for channels 0 and 12, 1 and 13, 2 and 14.
For the channels 3 and 15, select the value "1001(1v1) evaluation" for the "Evaluation of the sensors"
parameter.
28
CPU 317TF-3PN/DP: Controlling a SINAMICS S120 with Safety Functions
Getting Started, 10/2013, A5E02982990-04