Summary of
Programming
Commands
Special Messages
FUNCTION
ENTER PROGRAMMING MODE
EXIT PROGRAMMiNG MODE
ADVANCE TO FIELD
PROGRAM FIELD
ERASE FIELDS
READ FIELD
1. POWER UP, then depress
[X] and [#] both at once, within
50sec of powering up.
OR
2.
Initially, key: 4 +1 + 1 +1
plus CODE key + O.
OR
3.
If different Master Code is programmed,
key :
MASTER CODE + CODE KEY + O
(if 98 was used to exit previously,
method 1 above must be used to enter
the program mode again)
99
allows re-entry to programming mode
via type 2 or 3 entry method above.
* 98
inhibits re-entw to Droarammincl
mode via type'2 oi3 e}try metfiod.
[~] + Field No. (e.g., 21, 38, 56, etc.)
[x] + Field No., followed by data entries.
Some fields require sequential pressings of
[+$]to enter data (e.g., fields 56, 80,81~
[X] + Field No. + [X] (only applies to
fields 40 thru 44 and 94).
[#] + Field No. Data will either be
automatically sequentially displayed or can
be displayed by successively pressing [#].
OC =
OPEN CIRCUIT (no communication between Console and Control).
EE =
ERROR (program entry mistake). Re-enter the field number or data).
After powerina UD, AC. dl (disabled) or Svstem
Busv and NOT READY will
be displayed ~fie~ approximately 4 seconds: This will re~ert to READY in appx. 1
minute, which allows PIRS, etc. to stabilize. To bypass this delay, press: [#]+ [0].
If E4 or E8 appears, more zones than the expansion units can handle have been
programmed. Correct the program and then completely de-power and re-power
the control to clear this indication and remove the disable indication.