TO PROGRAM SYSTEM
STATUS & RESTORE
REPORT CODES
("60-"75)
With a 3+1 or 4+1 Standard Format: Enter a code in the
first
box: 1-9, 0, B,
C, D, E, or F. Enter "#+1 O" for O, "#+11" for B, "#+12" for C, "#+1 3" for D, "#+14"
for E, "#+15" for F.
A "O (not
"#+1O)
in the first box will disable a report.
A "0" (not "#+1 O) in the second box will result in automatic advance to the
next field when programming.
With an Expanded or 4+2 Format: Enter codes in both boxes (1st and 2nd
digits) for 1-9,0, or B-F, as described above.
A "O" (not "#+1 O) in the second box will eliminate the expanded message for
that report.
A "O (not "#+1O") in both boxes will disable the report.
With Ademco Contact ID Reporting:
Enter any digit (other than "O) in the
tirst box, to enable zone to report
This is an "enabling" code only and is
disregarded in the actual reporting to the central office. Entries in the second
boxes will be ignored.
A "O" (not "#+10") in the first box will disable the report.
See examples on programming form.
SYSTEM STATUS
*6O
REPORT CODES
(*60-*68)
*61
*62
63
*64
*65
66
*67
*68
RESTORE
*69
REPORT CODES
("69-"7!5)
*7O
7I
*72
*73
74
"75
(continued from page 26)
TROUBLE
REPORT
CODE
~
See box above.
BYPASS
REPORT
CODE
See box above.
AC LOSS REPORT
CODE
See box above.
LOW BAT REPORT
CODE
See box above.
TEST
REPORT
CODE
See box above.
OPEN
REPORT
CODE
See box above.
2nd digit = User #, if expanded or 4+2 reporting is selected.
CLOSE
REPORT
CODE
See box above.
2nd digit = User #, if expanded or 4+2 reporting is selected.
Report also sent for Arming STAY, if contact ID format is used.
RF XMTR. LOW BATTERY
REPORT CODE
See box above.
CANCEL
REPORT
CODE
See box above.
GROUP RESTORES
FOR TROUBLE,
RF LOW BATTERY,
BYPASS
Enter Ofor no (report for each restore)
or 1 for yes (report after all zones restored).
Note: "1"not applicable to Contact ID reporting.
ALARM
RESTORE
REPORT CODE, 1ST DIGIT
2nd digit is automatically sent as the 2nd digit of the zone alarm report
code programmed in field 56, if expanded or 4+2 reporting is selected.
TROUBLE
RESTORE
REPORT
CODE
See box above. Trouble restore is reported only if all troubles in the
system are restored, if field 69 is enabled.
BYPASS
RESTORE
REPORT
CODE
See box above.
AC RESTORE
REPORT
CODE
See box above.
LOW BAT RESTORE
REPORT
CODE
See box above.
RF XMTR, LOW BATTERY
RESTORE
See box above.