OUTPUT RELAY EXAMPLES
TABLE
RELAY
ACTION
DESIRED
START
STOP
ACTION
Zones in zone list (x) close relay for 2 seconds on alarms.
Zones in zone list (x) close relay for 2 secondson troubles.
Zones in zone list (x) close relay for 2 seconds on faults*.
Will activate relay for any zone type plus panics on 5801
whether control is armed or disarmed. (Console panics will
not activate a re/a y with
the configurations above.)
AI
EVIZLIZTIZLIZT
'
1111X
00
0
00
1
3
-x
00
0
00
1
2
x
00
0
00
Zones in zone list (x) close relay on alarms and reset at bell
2
1
x
00
0
36
timeout or when disarmed.
Zones in zone list (x) pulse relay on alarms and reset at bell
3
1
x
00
0
timeout or when disarmed.
36
Zones in zone list (x) close relay on alarms and reset when
2
1
x
00
x
00
zone is restored.*
Zones in zone list (x) pulse relay on alarms and reset when
3
1
x
00
x
00
zone is restored.*
'Console panics will not activate a relay with these
configurations. The reiay can also be activated by troubles
or faults by changing the EV (event) accordingly.
Zones in
zone list (x) close relay on alarms and reset when
disarmed. (Latchina relay for strobes,)*
Zones in zone list (x) pulse a relay on alarms and reset when
disarmed.*
*Relay will activate for burglaty, fire, and panic alarms if
programmed into zone /ist.
2
1
x
00
0
22
3
1
x
00
0
22
Close relay after any burglary alarm and reset when
disarmed.*
Close relay after any burglary alarm and reset at bell timeout
or when disarmed.*
*Response types 06,08, and 09 wi/i not activate re/ay. If
PULSE relay is desired, enter a 3 in A (action).
EEEF
~
o
22
0
36
Close relay when ARMED-AWAY, reset when DISARMED.*
2
0
0
21
0
22
Close relay when ARMED-STAY, resetwhen DISARMED.'
2
0
0
20
0
22
'If PULSED relav is desired, enter a 3 in A (action).
I
Close relay for 2 seconds at end of exit delay time after
1
0
0
31
0
00
system is armed (Confirmation ding).
Pulse relay at start of entry time and reset when system is
disarmed (entry warning).
3
0
0
32
0
22
Close relay for 2 seconds during chime. (Chime mode must
1
0
0
38
0
00
be turned on at control.)
-44-

Advertisement

Table of Contents
loading

Table of Contents