*45
PHONE
SYSTEM
SELECT
Enter 1 digit.
If Central Station Rcvr is not on WATS line:
O= Pulse Dial
1 = Tone Dial
If Central Station Rcvr /s on WATS line:
2 = Pulse Dial
3 =
Tone Dial
*46
REPORT
FORMAT
Detenine
which format is to
be used to report to the central station.
Enterl digit.
O= 3+1; 4+1 ADEMCO US Standard
1 = 3+1; 4+1 Radionics Standard
2 = 4+2 ADEMCO Lo Speed Standard
3 = 4+2 Radionics Standard
6 = 4+2 ADEMCO Express
7 = ADEMCO Contact ID Reporting
8 = 3+1; 4+1 ADEMCO Lo Speed Expanded
9 = 3+1; 4+1 Radionics Expanded
(Enter as
the 4th digit of 43, if 3+1 dialer
reporting is to be used.)
~ For explanation of these formats, seepage 33. ~
Note:
The maximum number of communicator reports during one
armed period is 10.
*47
SPLIT/DUAL
REPORTING
Enter Oto disable (Backup report only)
TO PRIMARY
TO
SECONDARY
1=
Alarms, Restore, Cancel
Others
2=
All except Open/Close, Test
Open/Close, Test
3=
Alarms, Restore, Cancel
All
4=
All except Open/Close, Test
All
5=
All
All
*48
15 SECOND
DIALER
DELAY
(BURGLARY)
Allows time for subscriber to avoid a false alarm transmission.
Enter Ofor no or 1 for yes
*49
PERIODIC
TEST
MESSAGE
Select the desired test report interval.
O = none; 1 = 24 hours; 2 = weekly
Test Report Code entered in field '64 is sent.
'50
SESCOA/RADIONICS
SELECT
O= Radionics (O-9, B-F reporting)
1 = SESCOA (O-9only reporting)
*51
CONFIRMATION
OF ARMING DING
Enter Ofor no or 1 for yes.
If selected, ding is external sounder only and will occur at time of kissoff of
closing report. If closing report is not programmed, ding will occur at end
of exit time.
w
-24-