ADEMCO via30 Installation Instructions Manual page 28

Hide thumbs Also See for via30:
Table of Contents

Advertisement

--------
---
. . . .
----
---
--------
---
.
..4.
9UTPUT
HELAY3
AND
ZONE LISTS
('80,
*81)
Output Relay Displays
*
I
02 Relay Action
No Response
O
I
m
Zone
Disabled 00
Ez-Hl
02 Stop:
Zn Typ
Zone Disabled 00
Em
E511
-Uu
UUIPUI
HELAYS
Applicable only if fieid *25 is programmed for a 4229 or 4204... otherwise
skip this field.
REFER TO THE OUTPUT RELAY TABLE FOR THIS FIELD
IN THE PROGRAMMING FORM.
Upon entering field '80, this screen will appear. Enter the Relay Number 01 or 02
for a 4229, or 01, 02, 03, or 04
for a 4204
(or 00 to end these entries). Press the
~] key to advance.
The data is keyed in and entered for this and the following screens by pressing ~].
To
back up to check an entry, press [#] for each position. Press [*] to go forward again.
This screen displays a summary of the current relay START programming (for this
example, relay 02 has been selected). Press the [*] key to advance.
This screen displays a summary of the current relay STOP programming. Press
the ~] key to advance.
Action (A): Enter the desired relay action. Press the ~] key to advance.
o = Not Used
2 = Close and
Stay Closed
1 = Close
for 2
seconds
3 = ContinualPulses
(1 see).On and Off
Event (EV): Enter the event to START the relay. Press the ~] key to advance.
o =
Not
used
2 =
Fault
1
Alarm
3 = Trouble
Zone List (ZL): if a
zone list will be used to START the
zone list number (to be programmed
in field *8 I ): 1, 2, or
Press the [*] key to advance.
relay action, enter the
3. If not used, enter O.
Zone
Type/System
Operation
(ZT): If a zone type or system operation will
be used to START the relay action, enter the appropriate two digit code. If not,
enter 00. Press the [*] key to advance.
CHOICES
FOR ZONE TYPES
00= No Response (Not Used)
01 = Entry/Exit
05= Trouble Day/Alarm Night
08 =24 HrAux
03 = Perimeter
06= 24 Hr Silent
09= Fire
04= Interior Follower
07= 24 Hr Audible
10 = Interior w/Delay
CHOICES
FOR SYSTEM
OPERATION
20= Arming-Stay
33= Any Burglary Alarm
38= Chime
21 = Arming–Away
34. Code+ #+7 Key Entry
39= Any Fire Alarm
22= Disarming (Code + OFF)
35. Code+ # + 8 Key Entry
40= Bypassing
31 = End of Exit Time
36= At Bell Timeout**
41 = AC Power Failure
32= Start of Entry Time
37= 2 times Bell Timeout**
42= System Battery Low
*Or at Disarming, whichever occurs earlier.
Restore Of Zone List (ZL): If a zone list will be used to STOP the relay ac-
tion, enter the zone list number (to be programmed in field '81): 1, 2, or 3. If not
used, enter O. Press the [*] key to advance.
Zone Type/System Operation (ZT): If a zone type or system operation will
be used to
STOP the relay action, enter the appropriate
two digit code (see the
"ZT"
choices listed above). If not, enter 00. Press the [*] key to advance.
This screen again displays a summary of the current relay START programming .
Press the [*] key to advance.
This screen again displays a summary of the current relay STOP programming.
Press the ~] key to return again to the first screen so that the next relay number to
be programmed can be entered, or enter [0][0] to end relay programming.
Note:
Previous/y entered data can be reviewed by pressing [#] [8] [0]. After the
relay number is chosen, press [#] to go to the next screens. This is a re-
view mode only, and data cannot be changed.
J.
-28–