PROGRAMMING
DATA FIELDS
ITHECENTERFOLD PROGRAMMING FORM CAN BE USED TO RECORD THE DATA FOR THIS INSTALLATION1
SYSTEM ARMING
('20-'25)
ZONE SOUNDSAND
TIMING
(28-38)
DIALER
PROGRAMMING
(40-50)
*2O
*21
"22
*23
*24
*25
*28
*29
*3O
*38
4O
41
*42
*43
MASTER
CODE
Enter 4 digits, O-9 (entry of all 4 is mandatory).
Use of a "9" in the last position inhibits the Ambush feature.
QUICK ARM ENABLE
If
enabled, [#]
key can be used instead of security code when arming the
system.
Enter Ofor disabled or 1 for enabled.
RF SYSTEM
TYPE
Select the RF system (receiver) type being used.
O= none; 1 = 5700 (4281); 2 = 5800 (5881)
FORCED
BYPASS
FUNCTION
All zones that are bypassed by this function will be displayed after the
bypass is initiated.
O= No forced bypass.
1 = Allows automatic bypass of all open zones.
RF RECEIVER
HOUSE ID CODE
MUST enter for 5700 system's 4281 type receiver, or 5800 system's
5827 keypad.
Enter 01-31 House ID.
WIRED
EXPANSION/OUTPUT
RELAY
USED
Select expansion/relay unit being used.
O = none; 1 = 4219; 2 = 4229; 3 = 4204
SINGLE ALARM SOUNDING PER ZONE (per armed period)
Enter Ofor no or 1 for yes
FIRE SOUNDER
TIMEOUT
DISABLE
Enter Oto enable the sounder timeout for fire or 1 to disable it.
ALARM
BELL
TIMEOUT
External sounder will shut off after time allotted. Enter 1 digit.
O= No timeout
2 = 8 minutes
1 = 4 minutes
3 = 12 minutes
ENTRY
DELAY
System will wait the time allotted before sounding alarm upon entering.
(EXIT delay = Entry delay plus 15 seconds)
O=
Oseconds
2 = 30 seconds
1 = 20 seconds
3 = 45 seconds
PABX ACCESS
CODE
Enter 4 digits, O-9, for each PABX digit needed to access an outside line.
To skip this field, enter . If
is entered, no PABX number will be dialed
and nothing will appear in this field. End field by entering 41 if not filled.
To clear entries from field, press "40'.
PRIMARY
PHONE
No.
Enter up to
12 digits,
O-9. Do not fill unused
spaces.
End field by
entering
42 if not filled. To clear entries from field, press *41*.
Note:
Back-up
reporling
(8 calls are made to the secondary
phone
number if no kiss-off is received after 8 attempts to the primary number) is
automatic only if there is a secondary phone number.
SECONDARY
PHONE
No.
See field '41 entry info. and Note. End field by entering
43 if not filled.
To clear entries from
field, press 42*.
SUBSCRIBER
ACCOUNT.
NO.
Enter digits O-9; #+1 l=B; #+12=C; #+13=D; #+14=E; or #+15=F.
Enter
as the fourth digit if a 3 digit acct no. (for 3+1 dialer reporting for-
mat) is used. Enter O as the first digit of a 4-digit acct no. for nos. 0000-
0999. End field by pressing
(and press next field) if only 3 digits are
used. To clear entries from field, press *43*.
–23-