Report Code Formats
The
Report
Codes
for
Alarm,
System
Status,
and
Restore
for
Zones shown in fields *56-*75 above can be selected
In field *46
to report to the central station in any of the following formats:
The 3+1 and 4+1 Standard formats comprise a 3 (or 4) digit subscriber
number and a single digit report code (e.g. Alarm, Trouble, Restore, Open,
Close).
The 3+1 and 4+1 Expanded formats comprise a 3 (or 4) digit subscriber
number, and a singledigit reportcode, followed by a second line where the report
code is repeated 3 (or 4) times and followed by another number (normally the
zone number)or user ID related to that report.
The 4+2 formats comprise either a 4 digit subscriber number and two digit
report code, or a 4 digit subscriber number and single digit reporl code,
immediately followed by the zone number (normally) or user ID.
The Ademco Contact ID Reporting format comprises a 4 digit subscriber
number, 1 digit event qualifier ("new" or "restore'"), 3 digit event code, 2 digit
"00, and 3 digit zone, contact ID, user, or system status number (see next page).
3+1/4+1
3+1/4+1
4+2
HmOrt
tandard
xrIanded
Alarm
SSS(S) A
Trouble
SSS(S) T
Bypass
SSS(S) B
AC LOSS
SSS(S) E
Low Batt
SSS(S) L
Open
Sss(s) o
Close
Sss(s) c
Test
SSS(S) G
Restore
SSS(S) R
Alarm
AC Restore
SSS(S) RA
LoBat Res.
SSS(S) RL
Trouble Res.
SSS(S) RT
Bypass Res.
SSS(S) RB
Where:
SSS or
SSSS = Subscriber ID
A = Alarm Code-1st digit
Z=
Typically Zone Number*-2nd digit
=
Trouble Code (1st & 2nd digits)
J
=
Bypass Code (1st & 2nd digits)
EAC .
AC Loss Code (1st & 2nd digits)
LLB =
Low Battery Code(lst & 2nd digits)
o=
Open Code-1st Digit
SSS(S) A
AAA(A) Z
SSS(S) T
11-r(l-) t
SSS(S) B
BBB(B) b
SSS(S) E
EEE(E) Ac
SSS(S) L
LLL(L) LB
Sss(s) o
000(0)
u
Sss(s) c
CCC(C)u
SSS(S) G
GGG(G)g
SSS(S) R
RRR(R)Z
SSS(S) RA
RARARA(RA)Ac
SSS(S) RL
SSS(S) RT
RfiTRT (RT)t
SSS(S) RB
RBRBRB (RB)b
c=
u=
Gg =
R=
RTt =
RBb =
RAAC =
RLLB .
Ssss
Az
SSSS Tt
SSSS Bb
SSSS EAc
SSSS LLB
Ssss Ou
Ssss Cu
SSSS Gg
Ssss Rz
SSSSRA AC
SSSS RLLB
RRR(RL)LB
SSSS RTt
SSSS RBb
Close Code-1st Digit
User Number (Ist & 2nd digits)
Test Code (lst & 2nd digits)
Restore Code (Alarm)l st & 2nd digits
Restore Code (Trbl)l st & 2nd digits
Restore Code (Byps)l st & 2nd digits
Restore Code (AC)l st & 2nd digits
Restore Code (Bat)l st & 2nd digits
Zone numbers for: ~u~j~j = 7
[1]+ [*]= 95
.
8
[3]+ [#]= 96
Tamper .
9
–33-