Zone Characteristics - ADEMCO via30 Installation Instructions Manual

Table of Contents

Advertisement

Zone Characterlstlcs
!ones
1-4
not present
!ones
5,6
Wired
Programmable
Zones.
EOLR
supervised,
N.0, or N.C. sensors, 300-500 msec normal response.
!ones
7, 95, 96 Console
Panics (Wired & Wireless). 24hr zones, pro-
grammable for silent, audible, auxiliary, or fire.
!one 8
Duress (see User's Manual).
!one 9
Tamper.
Reports faults in the expansion units (e.g.,
4219, 4229, 4281), tampers on 5800 system RF units
(5881), and trouble-by-day/alarm-by -night zones. For all
repori formats (except Contact ID, which provides more
explicit reporting) a trouble code is reported when the
system is not armed, and Zone 9 report code is sent for an
alarm.
additional
Up to 8 loops can be added, with a 4219 Wired
Mired
Expansion Unit or No. 4229 Wired Expansion/Relay Unit.
Vogrammabie
Loops are EOLR supervised, for N.O. or N.C. sensors,
tones
300-500
msec normai response, with optionai fast (1O-15
msec) response on ioop A (first expansion zone). Zone
numbers 10-17 should be assigned when using a 4219
or 4229 for zone expansion.
Alireiess
Zones
Up to 30 wireiess
(RF) zones
can be added
by
using an Ademco 4281(5700 System) or 5881 (5800
System) Type RF Receiver. Specificaiiy:
Modei
Number
of Zones
4281 L
up
to 4
4281 M15881L
Up to 8
5881M
Upto 16
4281 H/5881 H
up
to 30
Zone number assignments (which are also transmitter iD
assignments for 5700 RF system transmitters) can be in
the 10-63 range (18-63 when a 4219 or 4229 is aiso
used). A variety of RF system transmitters can be used to
make up the wireiess zones. This includes window/door
units, smoke detectors, PIRs, and panic keys.
Note: For
brevity, subsequent references
herein to the
RF Receiver will be indicated by "4281/5881" un-
less a specific model is named.
if (4219/4229)
wired
exDansion
zones
and
(4281/5881)
wireless
expansion
zones
are
~o be
added,
they can comprise
up to 8
(4219/4229) wired zones, pius wireiess zones up to the number permitted by
the type of 4281/5881 RF receiver used, as long as the tots/ does not exceec
the 30 expansion zones accommodated by the control.
For example: When aii 8 ioopsofa4219
or 4229 are to be used, a 4281H 01
5881H can add oniy 22 zones, so as not to exceed a totai of 30
expansion zones for this controi.
-5-