ZONE NPE
DEFINITIONS
General Information
00-
Zone Not Used
01 - Entry/Exit
Burglary
03- Perimeter
Burglary
04-
Interior, Follower
05-
Trouble by Day/
Alarm by, Night
06-
24-hour
Silent Alarm
07-
24-hour
Audible Alarm
08-
24-hour
Auxiliary Alarm
09- Supervised Fire
10- Interior w/Delay
Each zone must be assigned to a zone type, which defines the way in which the
system responds to faults in that zone. In addition, there are three keypad
-
activated zones (PANIC keys, see note below), and two RF supervisory zones for
the RF
Receiver
if installed. Zone types are defined below.
Program a zone with this zone type if the zone is not used.
This zone type provides entry delay whenever the zone is faulted if the control is
armed in the Away or Stay modes. When the panel is armed in the Instant or
Maximum modes, no entry delay is provided. Exit delay begins whenever the
control is armed, regardless of the arming mode selected. These delays are
programmable. This zone type is usually assigned to sensors or contacts on
doors through which primary entry and exit will take place.
This zone type gives an instant alarm if the zone is faulted when the panel is
armed in the Away, Stay, Instant or Maximum modes. This zone type is usually
assigned to all sensors or contacts on exterior doors and windows.
This zone type gives a delayed alarm (using the programmed Entry/Exit time) if
the Entry/Exit zone is faulted first. Otherwise this zone type gives an instant alarm.
This zone type is
active when the
panel is armed in the Away and Maximum
modes. This zone type is bypassed
automatically
when the panel k
armed in the Stay or Instant modes. This zone type is usually assigned to a
zone covering an area such as a foyer, lobby, or hallway through which one must
pass upon entry (After faulting the entry/exit zone to reach the console to disarm
the system.) Since this zone type is designed to provide an instant alarm if the
enty/exit zone is not violated first, it will protect an area in the event an intruder
hides on the premises prior to the system being armed, or gains access to the
premises through an unprotected area.
This zone type will give an instant alarm
if faulted when armed in the Away, Stay,
Instant or Maximum (night) modes.
During the disarmed state (day), the system
~,
will provide a latched trouble sounding from the console (and a central station
report, if desired). This zone type is usually assigned to a zone which contains a
foil-protected door or window (such as in a store), or to a zone covering a
"sensitive" area such as a stock room, drug supply room, etc. This zone type can
also be used on a sensor or contact in an area where immediate notification of an
entry is desired.
This zone type sends a report to the Central Station but provides no console
display or sounding. This zone type is usually assigned to a zone containing an
Emergency button.
This zone type sends a report to the Central Station, and provides a rapid
beeping sound at the console, and an audible external alarm. This zone type is
usually assigned to a zone that has an Emergency button.
This zone type sends a report to Central Station and provides a rapid beeping
sound at the console. (No bell output
is provided).
This zone type is
usually assigned to a zone containing a button for use in personal emergencies,
or to a zone containing monitoring devices such as water sensors, temperature
sensors, etc.
This zone type provides a fire alarm on short circuit and a trouble condition on
open circuit. The beil output will puise when this zone type is faulted. This zone
type is always active and cannot be bypassed. This zone type can be
assigned
to controi
panei wired
zone 5, any zone in a wired
zone
expansion
moduie,
or certain
wireiess
zones.
This zone type gives entry/exit delay (using the programmed entry/exit time), if
tripped when the panel is armed in the Away or Maximum modes. This zone
type
is bypassed
when the panei
is armed
in the Stay or instant
.
modes. Delay begins whenever sensors in this zone are vioiated, regardless of
~
whether or not an entry/exit delay zone was tripped first.