ADEMCO via30 Installation Instructions Manual page 29

Hide thumbs Also See for via30:
Table of Contents

Advertisement

Example of
Output Relay
Programming
Zone List Displays
m
I
03 Enter Zn Num.
(00 = Quit)
00
I
I
03 Del Zn List?
O= No I= Yes O I
I
03 Delete Zone?
O= Nol=Yes
O
I
03 Zn to Delete?
(00 = Quit)
00
I
DOWNLOAD
INFORMATION
(*94, *95)
Let us light an Indicator
when any one of 3 specific
zones are
faulted
or when any 24 hour aux. zone Is disturbed.
We want to
turn off the indicator
manually without
affecting
the arming status
of the system.
In field 8O we choose Output Relay 01 and program the Action (A) to be "2"
(Close and stay closed). The Event we are looking for to starlthe relay action is a
fault, so we will program "2" in (EV). We will use Zone List 1 for the 3 specific
zones, so will program"1 win (ZL), (and will program these 3 zones in field 81's
Zone List 1).
The second condition for turning on the indicator is triggering a 24 hour aux. zone
(Zone Type 08), so we will program (ZT) as "08.
To stop the relay action and turn off the indicator, we do not want to use a restore
of any zone, so we will program a "O for the Restore of Zone List (ZL). We will
choose a manual entry of User Code + [#] + [TJto turn it off, so will program (ZT) as
"34".
If no other relay is to be programmed we go to field '81 and program the 3 specific
zones in Zone List 1.
81
ZONE LISTS FOR OUTPUT
RELAYS
App/icab/e on/y if fie/d "25 is programmed for a 4229 or 4204.. otherwise
skip this field.
Upon entering field 81, this screen will appear. Enter the Zone List Number 01,
02, or 03 to program (or 00 to end these entries). Press the ['] key to advance.
In the following displays, zone list 03 has been selected for programming.
Enter each zone number to add to the zone list by first entering the zone number,
then the [*] key (ex., 01', 02', 03'). After all zones desired are entered, enter 00
to advance.
To delete the zone list, enter 1 (Yes). All zones in the zone list will be deleted
automatically. and programming will return to the first screen.
To save the zone list, enter O (No) to advance.
To save the entire zone list, enter O (No) and programming will return to the first
screen.
To delete a zone or zones in a zone list enter 1 (Yes) to advance.
Enter each zone to be deleted from the list, followed by the ~] key. After all zones
to be deleted are entered, enter 00 to return to the first screen so that another list
can be programmed, if desired. .
Notes:
" Any list may include any or all of the system's zone numbers.
A zone list can be assigned to more than one output relay.
If you only want to review what has been programmed previously,
enter [#][8][1 ]. The review can be advanced by using the [#] key.
When finished, enter [0][0] to quit. No programmed values can be
disturbed in this mode.
*82
CUSTOM
ALPHA
EDITING
[Also entered from field '56)
1 See ALPHA DESCRIPTIOIV ENTRIES section on page 30. {
*83
ADD/DELETE
5800 RF INPUT
iDs
See procedure in last paragraph of field *56.
*94
DOWNLOAD
PHONE
NUMBER
Enter up to 12 digits;O-9. Do not fill unused spaces.
End field by entering'. To clear entries from field, press 94'.
*95
RING DETECTION
COUNT FOR
DOWNLOADING
Enter number of rings before control picks up phone line (or Oor 15).
o=
1-14=
15 =
disable station initiated download
#of rings
answering machine defeat
-29–