General Information
Installer options are stored in non-removable, electrically erasable, non-volatile
EEROM memory. These options must be programmed for the particular installa-
tion to establish its specific alarm and reporting features.
Note:
It is possible to program the system at any time, even at the installer's
premises prior to the actual installation. Simply apply power temporarily to
the control and then program the unit as desired.
THE SECURITY
CONTROL
IS PROGRAMMED
VIA A 5137 OR 6139
CONSOLE (which need not necessarily remain in the system after program-
ming).
Note:
A 5137AD (Addressable) Console may be used, provided it is set to its
non-addressable mode (device ID 31. ..all DIP switch positions UP).
}
The initial sequence of entries should follow the order on the programming
sheet.
Certain programming fie/ds, such as those used to select the expansion devices
(fields 22 and 25) must be programmed before expansion zones can be pro-
grammed. If an expansion unit type is changed, the expansion zones should be
reprogrammed.
When programming, the field number will be displayed on the LCD display; also,
each entry is displayed as it is keyed in. After programming, values that have been
entered in each field can be reviewed and, if necessary, modified.
When programming from the console, note the following:
1. Enter the Programming mode by simultaneously depressing the ~] and [#]
keys within
50 seconds after power is applied to the Control, or
subsequently by keying the code 4 + 1 +
1 + 1
followed by depression of
CODE + O keys. If a different Master code is subsequently programmed,
use it instead of 4111 to gain access to the Programming mode. H the F?o-
gramming mode was exited previous/y using a *98, it wi// prevent entry info
the Programming mode by the use of the Master Code+ CODE+ O.
2.
Immediately following entry into the program mode, field 2Owill be displayed.
Following the above display, the system is ready to accept entries for field
'20.
3.
To program a data field, key ~] plus Field No. (for example, *21), then make
the required entry.
Some entries require sequential pressings of ~] to actually enter the data. This is
true in the Zone and Relay fields 56, '80, and 81 and the prompts will indi-
cate this. Entry of 1#1 will generally backup one entry position for review.
4.
5.
6.
7.
To simply review a data field, key [#] plus Field No.. Data will either be au-
tomatically sequentially displayed or can be displayed by successively press-
ing [#]. No changes will be accepted in this mode.
When a data field
has been completely programmed, the console will normally
"beep" three times and then automatically proceed to, and display, the next
data field number to be programmed (if not, key ~] plus the Field No. of the
next field to be programmed).
If the number of digits that you enter in the data field is less than the maximum
permitted (for example, phone number), then the console will display the last
data entered. To proceed, the next data field number to be programmed
must then be entered (for example, *42).
If a field is improperly entered, the console will display EE. Simply re-enter [*]
or [#] plus the field number.
-21-