Panasonic FP E Series User Manual page 333

Table of Contents

Advertisement

Name
Boolean
Basic function instructions
On-delay
TML
timer
TMR
TMX
TMY
Auxiliary
F137
timer (16-bit)
(STMR)
Auxiliary
F183
timer (32-bit)
(DSTM)
Counter
CT
UP/DOWN
F118
counter
(UDC)
Note:
*1) In the FP2/FP2SH/FP10SH, when timer 256 or higher, or counter 255 or lower, is used, the number
of steps is the number in parentheses. Also, in the FP2/FP2SH/FP10SH, when a timer number or
counter number has an index modifier, the number of steps is the number in parentheses.
Symbol
After set value "n" x 0.001 seconds, timer contact "a" is set
to on.
After set value "n" x 0.01 seconds, timer contact "a" is set
to on.
After set value "n" x 0.1 seconds, timer contact "a" is set to
on.
After set value "n" x 1 second, timer contact "a" is set to on.
After set value "S" x 0.01 seconds, the specified output and
R900D are set to on.
After set value "S" x 0.01 seconds, the specified output and
R900D are set to on.
Decrements from the preset value "n"
Increments or decrements from the preset value "S" based
on up/donw input.
Description
Steps
(*1)
3 (4)
3 (4)
3 (4)
4 (5)
5
7
3 (4)
5
12-41