FPΣ 32k type
Item
External input
External output
(Y)
Note2)
Internal relay
Note2)
Link relay
Note2)
Timer
(T)
Note2)
Counter
(C)
Special internal relay
(R)
External input
(WX)
External output
(WY)
Note2)
Internal relay
(WR)
Link relay (WL)
Note2)
Data register
Note2)
Link register
Timer/Counter set
Note2)
value area
Timer/Couner elapsed
Note2)
value area
Special data register
(DT)
Index register (I)
Master control relay
points (MCR)
Number of labels
(JP and LOOP)
Number of step
ladders
Number of
subroutines
Number of interrupt
programs
Decimal constants
(Integer type) (K)
Hexadecimal
constants (H)
Decimal constants
(Floating point type)
(F)
Note1)The number of points noted above is the number reserved as the calculation memory. The actual
number of points available for use is determined by the hardware configuration.
10-16
Number of points and
range of memory area
available for use
C32TH/C32THTM
C32T2H/C32T2HTM
C24R2H/C24R2HTM
C28P2H/C28P2HTM
Note1)
(X)
1184 points (X0 to X73F)
Note1)
1184 points (Y0 to Y73F)
(R)
4096 points (R0 to R255F)
(L)
2048 points (L0 to R127F)
1024 points (T0 to
T1007/C1008 to C1023)
176 points (R9000 to R910F)
Note1)
74 words (WX0 to WX73)
Note1)
74 words (WY0 to WY73)
256 words (WR0 to WR255)
128 words (WL0 to WL127)
32765 words (DT0 to
(DT)
DT32764)
(LD)
256 words (LD0 to LD255)
1024 words (SV0 to SV1023)
(SV)
1024 words (EV0 to EV1023)
(EV)
260 words (DT90000 to
DT90259)
14 words (I0 to ID)
256
256
1000 stages
100 subroutines
9 programs (8 external input points "X0 to X7", 1 periodical interrupt point "0.5
ms to 30s")
K-32, 768 to K32, 767 (for 16-bit operation)
K-2, 147, 483, 648 to K2, 147, 483, 647 (for 32-bit operation)
H0 to HFFFF (for 16-bit operation)
H0 to HFFFFFFFF (for 32-bit operation)
F-1.175494 x 10
F-1.175494 x 10
Turns on or off based on external input.
Externally outputs on or off state
Relay which turns on or off only within
program.
This relay is a shared relay used for PLC link.
This goes on when the timer reaches the
specified time. It corresponds to the timer
number.
Note3)
This goes on when the timer increments. It
corresponds to the timer number.
Relay which turns on or off based on specific
conditions and is used as a flag.
Code for speciyfying 16 external input points
as one word (16 bits) of data.
Code for specifying 16 external output points
as one word (16 bits) of data.
Code for specifying 16 internal relay points as
one word (16 bits) of data.
Code for specifying 16 link relay points as one
word (16 bits) of data.
Data memory used in program. Data is
handled in 16-bit units (one word).
This is a shared data memory which is used
within the PLC link. Data is handled in 16-bit
units (one word).
Data memory for storing a target value of a
timer and setting value of a counter. Stores by
timer/counter number
Data memory for storing the elapsed value
during operation of a timer/counter. Stores by
timer/counter number.
Data memory for storing specific data. Various
settings and error codes are stored.
Register can be used as an address of
memory area and constants modifier.
-38
38
to F-3.402823 x 10
-38
38
to F-3.402823 x 10
Function