No.
DT90194
to
Not used
DT90199
DT90200
High-speed
counter
DT90201
elapsed value
DT90202
High-speed
counter target
value
DT90203
DT90204
High-speed
counter
DT90205
elapsed value
DT90206
High-speed
counter target
value
DT90207
DT90208
to
Not used
DT90218
12-32
Name
-
The elapsed value (32-bit data) for the high-
For
speed counter is stored here. The value can
CH2
be read and written by executing the F1 (DMV)
instruction.
The targe value (32-bit data) of the high-speed
counter specified by the high-speed counter
instruction is stored here. Target values have
For
been preset for the various instructions, to be
CH2
used when the high-speed counter related
instruction F166, F167, F171, F175 or F176 is
executed. The value can be read by executing
F1 (DMV) instruction.
The elapsed value (32-bit data) for the high-
For
speed counter is stored here. The value can
CH3
be read and written by executing F1 (DMV)
instruction.
The target value (32-bit data) of the high-
speed counter specified by the high-speed
counter instruction is stored here. Target
For
values have been preset for the various
CH3
instructions, to be used when the high-speed
counter related instruction F166 or F167 is
executed. The value can be read by executing
the F1 (DMV) instruction.
Descriptions
Read-
Writ-
ing
ing
N/A
N/A
A
A
A
N/A
A
A
A
N/A
N/A
N/A