Panasonic FP E Series User Manual page 277

Table of Contents

Advertisement

High-speed counter, pulse output and PWM output specifications
Item
No. of input
points
Used ch.
Max. counting
speed
High
speed
coun-
Input mode
ter
Input contact
Note1)
used
No. of output
points
Note2)
Used ch
Output mode
Max. output
Pulse
frequency
output
Input/output
contact used
Note1)
No. of output
points
Note2)
Used ch
Output
PWM
frequency
output
Output duty
Output
contact used
Note1)
Note1)The contacts noted above cannot be allocated for more than one function. Also, contacts that are
not assigned to the various functions can be used as general inputs/outputs. Inputs functions can
be used as general inputs/outputs. Inputs X0 to X5 are pulse catch inputs, and can also be used
for interrupt input.
Note2)The pulse output, PWM output and high-speed counter of the same channel cannot be used at
the same time.
When using single-phase: Max. 4
channels
Note2)
ch0 to ch4
When using single-phase:
for 1 channel: Max. 50kHz (x1ch)
for 2 channels: Max. 30kHz (x2ch)
for 3 or 4 channels: Max. 20kHz (x3
to 4ch)
When using single-phase:
Addition input,
Subtraction input
When using single-phase:
X0: count input (ch0)
X1: count input (ch1)
X2: reset input (ch0, ch1)
X3: count input (ch2)
X4: count input (ch3)
X5: reset input (ch2, ch3)
Max. 2 channels
ch0, ch2
CW and CCW mode, Pulse and Sign mode
When using 1 channel: Max.
100kHZ (x1ch)
When using 2 channels: Max.
60kHz (x2ch)
<ch0>
X2: Home input
Y0: CW output (Pulse output)
Y1: CCW output (Sign output)
Y2: Deviation counter reset output
Max. 2 channels
ch0, ch2
1.5 to 12.5kHz (at resolution of 1000), 15.6 to 41.7kHZ
(at resolution of 100)
0.0 to 99.9% (at resolution of 1000), 1 to 99% (at reslution of 100)
<ch0>Y0, <ch2>Y3
Descriptions
When using 2-phase: Max. 2
channels
ch0, ch2
When using 2-phase:
for 1 channel: Max. 20kHz (x1ch)
for 2 channels: Max. 15kHz (x2ch)
When using 2-phase:
Two-phase input, One input,
Direction distinction input
When using 2-phase:
X0, X1: count input (ch0)
X2: reset input (ch0)
X3, X4: count input (ch2)
X5: reset input (ch2)
When using linear interpolation
function: Max. 100kHz
When using circular interpolation
function: Max. 20kHz
<ch2>
X5: Home input
Y3: CW output (Pulse output)
Y4: CCW output (Sign output)
Y5: Deviation counter reset output
10-9