1:1 communication with Micro-Imagechecker
Overview
The FPΣ and Micro-Imagechecker A200/A100 are connected using an RS232C cable. The results of the
scan are stored in the data registers of the FPΣ.
• After the scan start code "%S
Micro-Imagechecker as the response.
Communication format settings for Micro-Imagechecker
To set the communication mode and communication format settings for the Micro-Imagechecker, select
"5: communication" under "5: ENVIRONMENT" on the main menu, and the set the following items.
No.
No. 51
Communication mode
No. 52
Serial settings
No. 53
Serial output settings
Key Point:
• If "Del" is specified for the invalid processing parameter, zero suppression processing will be carried
out on the output data, and the output format will be changed. Always make sure "Repl. 0" is specified.
• When outputting data to an external device, numerical calculation is required, so "Out" should be
specified for the "Numerical calculation" parameter.
• With the above settings, the following data will be output from the Micro-Imagechecker.
7-50
" has been sent from the FPΣ side, the scan result is returned from the
C
R
Name
Set Value
Normal mode
Baud rate: .............
Bit length: ..............
Stop bit: .................
Parity : ...................
Flow control: ...........
Output digit: ............
Invalid Digit: ..........
Read End: ..............
Process End: ..........
Numerical calculation:
Judgment: .............
9600 bps
8 bits
1 bit
None/Odd
None
5 column
Repl. 0
None
None
Output
Output