X2 Profinet - Siemens PPU 26x.3 series Manual

Ppu and components
Table of Contents

Advertisement

Cable specification:
Features
Connection option
Current carrying capacity
Max. cable length
7.8.3.2

X2 PROFINET

Requirement
The I/O module has certified PROFINET interfaces, however their functionality cannot be fully
utilized within the scope of the SINUMERIK 828D control system. Networking within
SINUMERIK 828D is performed via a PLC I/O interface, which is based on PROFINET.
X2 pin assignment: Port 1 and port 2
Pin
1
2
3
4
5
6
7
8
Data transmission
The interfaces are designed for operation in full-duplex mode, i.e. for sending and receiving
data. When connecting I/O modules to the SINUMERIK 828D, please use the preassembled
SINAMICS DRIVE-CLiQ signal cables; from a technical point of view, these are also suitable
for use with PROFINET:
● Article number: 6FX2002-1DC00-...
● The transmission characteristics of these cables meet the requirements of CAT5.
● Data transmission rate: 100 Mbps (fast Ethernet).
● The maximum length of the connections between the terminal device and network
component or between two network components must not exceed 70 m.
PPU and components
Manual, 10/2015, 6FC5397-2DP40-5BA3
Signal name
Signal type
TX+
O
TX-
O
RX+
I
N.C.
-
N.C.
-
RX-
I
N.C.
-
N.C.
-
7.8 PP 72/48D PN and PP 72/48D 2/2A PN
Version
Up to 2.5 mm
2
Max. 10 A
10 m
Meaning
Transmit data +
Transmit data -
Receive data +
Not assigned
Not assigned
Receive data -
Not assigned
Not assigned
Connectable components
207