Note
Terminal M1 must be connected for the digital inputs (DI) 0 to 3 and 16/17 to function. This
can be done as follows:
● Connect the ground reference of the digital inputs.
● Jumper to terminal M: This removes the electrical isolation for these digital inputs.
Parameter
Current consumption
Galvanic isolation
As an input
Voltage
Current consumption
Signal level (including ripple)
Signal propagation times
As an output
Voltage
Max. load current
PPU and components
Manual, 10/2015, 6FC5397-2DP40-5BA3
Value
Typical: 10 mA at 24 VDC
The reference potential is terminal M1
-3 V to 30 V
Typical: 10 mA at 24 VDC
High signal level: 15 V to 30 V
Low signal level: -3 V to 5 V
Inputs / "fast inputs":
L → H: Approx. 50 μs/5 μs
H → L: Approx. 100 μs/50 μs
24 VDC
Per output: 500 mA continuous short-circuit proof
Connectable components
7.9 NX10.3 / NX15.3