Assembling - Siemens PPU 26x.3 series Manual

Ppu and components
Table of Contents

Advertisement

Name
H5
H6
Note
When the system is booting, LEDs H1, H2 and H3 are lit.
7.8.2

Assembling

Mounting
The I/O module is screwed with a mounting plate to the control cabinet wall in the control
cabinet. The module must be installed according to EN 60204.
Protection against electric shock
A protective conductor must be connected using the grounding screw.
Mounting versions:
● Portrait mounting at the lateral strap of the mounting plate (2x M5 or M6 screws).
● Flat mounting at the rear wall of the mounting plate (4x M5 or M6 screws).
PPU and components
Manual, 10/2015, 6FC5397-2DP40-5BA3
Designation
Color
DIAG2
Green
OVTemp
Red
WARNING
7.8 PP 72/48D PN and PP 72/48D 2/2A PN
Description
Reserved
Overtemperature display
Connectable components
201