Mounting - Siemens PPU 26x.3 series Manual

Ppu and components
Table of Contents

Advertisement

Connectable components
7.5 MCP 310C PN
LEDs for status display
Table 7-45
LEDs
Name
Designation
H1
PowerOK
H2
PNSync
H3
PNFault
Note
When the system is booting, all three LEDs are lit.
7.5.2

Mounting

Mounting position
The permitted mounting position is max. 60° to the vertical.
Note
For mounting position greater than 60°, a fan must also be installed to keep the ambient
temperature of the machine control panel constantly below 55° C.
166
Color
Description
Green
Lit: Power supply ok
Green
Lit: System software running, STOP state
Flashes 0.5 Hz: System software running, RUN state
Red
Not lit: Module is operating without errors; data exchange with all configured I/O devices
is running.
Lit: Serious bus fault; only output when one of the following errors is detected for the ports:
● No physical connection to a subnet/switch
● Incorrect transmission rate
● Full duplex transmission is not activated
PPU and components
Manual, 10/2015, 6FC5397-2DP40-5BA3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents