In the case of operation without a Pt100 element, a slightly negative voltage may be applied,
which results in an error status for the module. Observe the "PNFault" LED and the status
byte 1.
Analog output measured values
"Voltage output" operating mode:
16-bit value (hex.)
Overflow
Overrange
0x6666
0x4CD1
0x199B
0x0000
0xE665
0xB32F
0x999A
Underrange
Underflow
"Current output" operating mode:
16-bit value (hex.)
Overflow
Overrange
0x6666
0x4CD1
0x199B
0x0000
0xE665
0xB32F
0x999A
Underrange
Underflow
7.8.4

Assigning parameters

7.8.4.1

Parameter assignment of the digital inputs/outputs

Input image of the digital inputs
The input image for the 1st I/O module (n=0) contains the following digital inputs (DI): n+0 ...
n+8 (9 bytes)
PPU and components
Manual, 10/2015, 6FC5397-2DP40-5BA3
16-bit value (dec.)
26214
19665
6555
0
-6555
-19665
-26214
16-bit value (dec.)
26214
19665
6555
0
-6555
-19665
-26214
Connectable components
7.8 PP 72/48D PN and PP 72/48D 2/2A PN
Factor
Voltage value [V]
-
Deactivation
-
Up to 10.5 V
10 V
7.5 V
2.5 V
0.000381469
0 V
-2.5 V
-7.5 V
-10 V
-
Up to -10.5 V
-
Deactivation
Factor
Current value [V]
-
Deactivation
-
20.2 mA
20 mA
15 mA
5 mA
0.0007629
0 mA
-5 mA
-15 mA
-20 mA
-
-20.2 mA
-
Deactivation
219