Siemens PPU 26x.3 series Manual page 83

Ppu and components
Table of Contents

Advertisement

Connecting the inputs and outputs:
● Recommended connection: Inputs and outputs connected to the same supply
If both inputs and outputs are operated with the same 24 V supply.
● Not recommended connection: Inputs and outputs on different supplies
X242 pin assignment
Pin
1
2
3
4
5
6
7
8
9
10
PPU and components
Manual, 10/2015, 6FC5397-2DP40-5BA3
NOTICE
Exceeding the permissible input current
If the inputs and outputs are supplied separately with power, the input current can exceed
the permissible value of 15 mA according to EN61131-2, and the signal source can be
overloaded.
Signal name
Not connected
Not connected
IN1
DIN1
IN2
DIN2
IN3
DIN3
IN4
DIN4
M4
MEXT4
P3
P24EXT3
O1
DOUT1
O2
DOUT2
NC variable
Meaning
$A_IN[1]
Digital NC input 1
$A_IN[2]
Digital NC input 2
$A_IN[3]
Digital NC input 3
$A_IN[4]
Digital NC input 4
Ground for pins 3...6
+24 V power supply
$A_OUT[1]
Digital NC output 1
$A_OUT[2]
Digital NC output 2
Interface description
6.5 Digital inputs/outputs
83

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents