Connectable components
7.3 MCP Interface PN
Table 7-15
Pin
1
2
3
4
Table 7-16
Parameter
Voltage:
Max. load current:
UL certified rating
Handwheel X60 / X62
Via X60, you can connect one handwheel either with TTL or difference signals. Alternatively,
you can connect the handwheel via X62. You can connect only one handwheel to the module
because the signals from X60 are fed parallel to X62.
Use switch S2 to switch between TTL and difference signals.
Note
The handwheel is supplied by the MCP module with 5 V / 100 mA. An external power supply
is not permitted.
NOTICE
Handwheel connections
The SINUMERIK 828D software can process up to three handwheels. You can connect two
handwheels to the PPU. You can connect an additional handwheel to the machine control
panel.
Connector designation:
Connector type:
134
Assignment of connector X58
Signal name
DO121.4
DO121.5
DO121.6
M
Technical data for X53, X54 and X56 to X58
X60
15-pin Sub-D socket
Type
Meaning
24 V output 12 (group 2)
O
24 V output 13 (group 2)
24 V output 14 (group 2)
V
Ground
Value
Nominal: 24 V
Permissible: 18 V to 30 V
Per output: 0.7 A
Per connector: 1 A
Per output at 100% simultaneity of all 15 outputs: 0.15 A
Each output:
24 V / 0.15 A general, resistive load
24 V / 3.6 W lamp load
24 V / 0.15 A coil load
PPU and components