7.10 Activating and addressing components

7.10
Activating and addressing components
7.10.1

Activating components

Machine data for the PLC I/O
The following components are assigned fixed addresses for the input and output image of the
PLC: I/O modules, machine control panel, SENTRON PAC and PN/PN coupler.
To deactivate the update of the input and output images of the PLC, set the following machine
data:
Machine data
12986[i]
12987[i]
The SINUMERIK 828D works with a fixed maximum configuration of the I/O modules. As
delivered, the data transfer to the input and output image of the PLC is deactivated for all I/O
modules.
To activate a PN component, you must enter the value -1 ("empty") in MD12986[i], see the
table in Section Addressing components (Page 239). MD12987[i] is preset with the value -1
and must not be changed.
Machine control panel
To activate the machine control panel, check the setting of the following machine data:
Machine data
MD12950 $MN_PLC_MCP_CONNECT
MD12951 $MN_PLC_MCP_CONNECT
MD12952 $MN_PLC_MCP_CONNECT
MD12986 $MN_PLC_DEACT_IMAGE_LADDR_IN
MD19720 $MN_PLC_FUNCTION_MASK
Example
In this example, two I/O modules and a machine control panel of the PN type are activated:
MD
12986[0]
12986[1]
238
$MN_PLC_DEACT_IMAGE_LADDR_IN
$MN_PLC_DEACT_IMAGE_LADDR_OUT
[0]
[1]
[0]
[1]
[0]
[1]
[6]
Bit 0
Logical input address
-1
-1
Value range
0 ≤ i ≤ 15
0 ≤ i ≤ 15
MCP type PN
Addressing via im‐
Addressing via
age
DB1000
0
-1
112
0
112
0
-1
0
Data transfer to the PLC deactivated
1st PP module active
2nd PP module active
Manual, 10/2015, 6FC5397-2DP40-5BA3
Input addresses
Output addresses
MCP type USB
Addressing via
DB1000
0
1
-1
-1
112
112
0
0
112
112
0
0
-1
112
1
0
PPU and components