Siemens Simatic ET 200SP Manual page 232

Analog input module ai energy meter 480vac/ct hf (6es7134-6pa00-0cu0)
Hide thumbs Also See for Simatic ET 200SP:
Table of Contents

Advertisement

Byte
Measured variable
270...273
Fundamental current L3
274...277
Fundamental apparent power L1
278...281
Fundamental apparent power L2
282...285
Fundamental apparent power L3
286...289
Fundamental reactive power L1
290...293
Fundamental reactive power L2
294...297
Fundamental reactive power L3
298...301
Fundamental active power L1
302...305
Fundamental active power L2
306...309
Fundamental active power L3
310...313
Fundamental cos φ active factor L1
314...317
Fundamental cos φ active factor L2
318...321
Fundamental cos φ active factor L3
322...325
Harmonic distortion (THD+N) voltage L1
326...329
Harmonic distortion (THD+N) voltage L2
330...333
Harmonic distortion (THD+N) voltage L3
334...337
Harmonic distortion (THD+N) current L1
338...341
Harmonic distortion (THD+N) current L2
342...345
Harmonic distortion (THD+N) current L3
346...358
Current module time
Neutral current
If you operate the AI Energy Meter HF with connection type 3P4W, 3P4W1 or 3P3W, the
neutral current is also calculated under the following conditions:
● Transmission factors of all phase currents (primary and secondary currents) are identical.
● Measured phase currents are greater than the value of the "Low limit for measuring
current parameter.
● The parameter "Reverse current direction" must be the same on all phases.
If one of the conditions is not met, 0 is entered as the value for the neutral current. You can
read the neutral current calculated using measured value data record 142.
Procedure
Data record 142 is located on the AI Energy Meter HF. Use the RDREC instruction to read
out the data record from the module. This system function block is stored in the STEP 7
library.
Analog input module AI Energy Meter 480VAC/CT HF (6ES7134-6PA00-0CU0)
Manual, 07/2018, A5E42674880-AA
E.2 Measured value data record for base measurements (DS 142)
Data
type
REAL
REAL
REAL
REAL
REAL
REAL
REAL
REAL
REAL
REAL
REAL
REAL
REAL
REAL
REAL
REAL
REAL
REAL
REAL
PNI-
OTime
Measured value data records
Unit
Value range
A
0.0 ... 100000.0
VA
-3.0 x 10
... +3.0 x 10
9
VA
-3.0 x 10
... +3.0 x 10
9
VA
-3.0 x 10
... +3.0 x 10
9
var
-3.0 x 10
... +3.0 x 10
9
var
-3.0 x 10
... +3.0 x 10
9
var
-3.0 x 10
... +3.0 x 10
9
W
-3.0 x 10
... +3.0 x 10
9
W
-3.0 x 10
... +3.0 x 10
9
W
-3.0 x 10
... +3.0 x 10
9
-
-1.0 ... 1.0
-
-1.0 ... 1.0
-
-1.0 ... 1.0
1%
0% to 100%
1%
0% to 100%
1%
0% to 100%
1%
0% to 100%
1%
0% to 100%
1%
0% to 100%
sec
Meas-
ured
value
ID
62323
62125
9
62225
9
62325
9
62124
9
62224
9
62324
9
62126
9
62226
9
62326
9
62127
62227
62327
62120
62220
62320
62121
62221
62321
65497
231