DGX 1600
Front Panel
The front panel of DGX 1600 Enclosures features an LCD screen, Control Panel, Input and Output keys and Power Indicator
LED (FIG. 4):
Control Panel
(Control keys/Dial)
FIG. 4
DGX 1600 - Front Panel Components
Power Indicator LED Behavior
Green – both power supplies are powered on
Red – one of the power supplies is not receiving power or has failed
Off – neither power supply is receiving power
Rear Panel
Enova DGX 1600 enclosures have eight horizontal I/O board slots (four slots each for input and output boards with four
connectors each), allowing for a maximum configuration of 16x16. FIG. 5 shows the rear panel of an DGX 1600 enclosure,
fully loaded for 16x16 switching:
Input board
slots (x4)
Expansion slot
(with expansion
board installed)
FIG. 5
DGX 1600 - Rear Panel Components
Power Supplies (x2)
The ENC 1600 has two power supply units. Each of the power supply units has a power receptacle that will accept all
major international standard power sources. (US power cords are included with all enclosures shipped within the US.)
Maximum power specifications are provided on the power supply receptacles.
AC LED
DC LED
FIG. 6
ENC 1600 Power Supply
NOTE:
For information on applying power, see page 63.
Enova Digital Media Switchers - Hardware Reference Manual
LCD
CPU/Control board
Power Indicator LED
Numbering plate
Power supplies (x2)
AC: Green light indicates power is good
DC: Green light indicates power is good
Amber light indicates temperature is above normal
Red light indicates that the power supply is in a fault state
DGX 1600
Input keys
Output keys
Output board
slots (x4)
Expansion slot
(with expansion
board installed)
37