Chapter 9 Troubleshooting

9.3 Clearing Faults

Display
Overcurrent
Overvoltage
Undervoltage
Motor error
Regeneration error
Overload
Overspeed
Abnormal pulse control
command
Excessive deviation
Reserved
Encoder error
Adjustment error
Emergency stop activated
Reverse limit switch error
Forward limit switch error
IGBT temperature error
Memory error
Encoder output error
9-12
info@varitel.com - www.varitel.com - Tel. (54) 11-4243-1171 / Fax: (54) 11-4292-7545
Manuel Baliña 456, Lomas de Zamora (B1832CCJ) Buenos Aires, Argentina.
VARITEL INGENIERIA ELECTRONICA S.A.
Fault Name
Clearing Method
Turn ARST (DI signal) ON to clear the fault
or restart the servo drive.
Turn ARST (DI signal) ON to clear the fault
or restart the servo drive.
This fault message can be removed
automatically after the voltage has returned
within its specification.
This fault message can be removed by
restarting the servo drive.
Turn ARST (DI signal) ON to clear the fault
or restart the servo drive.
Turn ARST (DI signal) ON to clear the fault
or restart the servo drive.
Turn ARST (DI signal) ON to clear the fault
or restart the servo drive.
Turn ARST (DI signal) ON to clear the fault
or restart the servo drive.
Turn ARST (DI signal) ON to clear the fault
or restart the servo drive.
This fault message cannot be cleared.
This fault message can be removed by
restarting the servo drive.
This fault message can be removed after the
wiring of CN1 connector (I/O signal
connector) is removed and auto adjustment
function is executed.
This fault message can be removed
automatically by turning off EMGS (DI
signal).
Turn ARST (DI signal) ON to clear the fault.
This fault message can be removed when
the servo drive is Off (Servo Off)
Turn ARST (DI signal) ON to clear the fault.
This fault message can be removed when
the servo drive is Off (Servo Off)
Turn ARST (DI signal) ON to clear the fault
or restart the servo drive.
Turn ARST (DI signal) ON to clear the fault
or restart the servo drive.
Turn ARST (DI signal) ON to clear the fault.
ASDA-B2