Detailed Parameter Listings; Group 0: P0-Xx Monitor Parameters - Delta Electronics ASDA-B2 series User Manual

Delta standart ac servo drive of general-purpose applications
Table of Contents

Advertisement

Chapter 7 Servo Parameters

7.3 Detailed Parameter Listings

Group 0: P0-xx Monitor Parameters

P0-00★
VER
Operation
Interface:
Default: Factory setting
Control
Mode:
Unit: -
Range: -
Data Size: 16-bit
Display
Format:
Settings:
This parameter displays the firmware version of the servo drive.
P0-01■
ALE
Operation
Interface:
Default: -
Control
Mode:
Unit: -
Range: 0 ~ 0 (0: clear the fault or restart the servo
Data Size: 16-bit
Display
Format:
Settings:
This parameter shows the current servo drive fault if the servo drive is currently
faulted.
The fault code is hexadecimal data but displayed in BCD format (Binary coded
decimal).
Servo Drive Fault Codes:
001: Overcurrent
002: Overvoltage
003: Undervoltage (This fault code shows when main circuit voltage is below its
minimum specified value while Servo On, and it will not show while Servo Off.
This fault code can't be cleared automatically after the voltage has returned
within its specification. Please refer to parameter P2-66.)
004: Motor error (The drive and motor are not correctly matched for size (power
rating).
005: Regeneration error
006: Overload
7-10
info@varitel.com - www.varitel.com - Tel. (54) 11-4243-1171 / Fax: (54) 11-4292-7545
Manuel Baliña 456, Lomas de Zamora (B1832CCJ) Buenos Aires, Argentina.
VARITEL INGENIERIA ELECTRONICA S.A.
Firmware Version
Keypad/Software
ALL
Decimal
Drive Fault Code
Keypad/Software
ALL
drive, the same function of ARST (DI signal))
BCD
Communication
Communication
ASDA-B2
Address: 0000H
0001H
Related Section: N/A
Address: 0002H
0003H
Related Section:
Section: 11.1
Section: 11.2
Section: 11.3
Revision September 2013

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents