Electronic Gear Ratio - Delta Electronics ASDA-B2 series User Manual

Delta standart ac servo drive of general-purpose applications
Table of Contents

Advertisement

ASDA-B2
Using parameter P1-01 can select P mode. Electronic gear ratio can be set in P
modes to set proper position revolution. ASDA-B2 series servo drive also provides
low-pass filter, which are used whenever the motor and load need to be operated more
smoothly. As for the information of electronic gear ratio, and low-pass filter, please
refer to the following sections 6.2.3 and 6.2.4.
Pulse Inhibit Input Function (INHP)
INHP is activated via digital inputs (Please refer to parameter P2-10 ~ P2-17,P2-36
and DI INHP(07) in Table 7.1).When the drive is in position mode, if INHP is activated,
the external pulse input command is not valid and the motor will stop.

6.2.3 Electronic Gear Ratio

Relevant parameters:
P1-44▲
GR1
Operation
Interface:
Default: 16
Control
Mode:
Unit: pulse
Range: 1 ~ (2
Data Size: 32-bit
Display
Format:
Settings:
This parameter is used to set the numerator of the electronic gear ratio. The
denominator of the electronic gear ratio is set by P1-45. P2-60 ~ P2-62 are used to
set the additional numerators.
Revision September 2013
info@varitel.com - www.varitel.com - Tel. (54) 11-4243-1171 / Fax: (54) 11-4292-7545
Manuel Baliña 456, Lomas de Zamora (B1832CCJ) Buenos Aires, Argentina.
VARITEL INGENIERIA ELECTRONICA S.A.
Electronic Gear Ratio (1st Numerator) (N1)
Keypad/Software
PT
26
-1)
Decimal
Chapter 6 Control Modes of Operation
Communication
Address: 0158H
0159H
Related Section:
Section 6.2.3