NEC UNIVERGE SV9100 Features And Specifications page 1283

Hide thumbs Also See for UNIVERGE SV9100:
Table of Contents

Advertisement

Program
Program Name/Description
Number
ARS/F-Route Table – Maximum Digit
44-05-09
Input the maximum number of digits to send
when using the F-Route.
ARS/F-Route Table – CCIS over IP
44-05-10
Destination Point Code
Input the Destination Point Code to send when
using F-Route.
ARS/F-Route Table – Network Specified
44-05-11
Parameter Table
Enter a table number from Program 26-12.
44-06-01
Additional Dial Table
Set the additional dial table to add prior to the
dialed ARS/F-Route Number. The Additional
Dial Table used is determined in Program
44-05-03. Define the additional dial table
(1 ~ 1000) to add digits in front of the dialed
ARS/F-Route number.
Gain Table for ARS/F-Route Access –
44-07-01
Incoming Transmit
Gain Table for ARS/F-Route Access –
44-07-02
Incoming Receive
Gain Table for ARS/F-Route Access –
44-07-03
Outgoing Transmit
Gain Table for ARS/F-Route Access –
44-07-04
Outgoing Receive
44-08-01
Time Schedule for ARS/F-Route
Define the daily pattern of the ARS/F-Route
feature. ARS/F-Route has 10 time patterns.
These patterns are used in Program 44-09 and
Program 44-10. The daily pattern consists of 20
time settings.
Input Data
0 ~ 24
0 ~ 16367
0 ~ 16
Maximum of 24 digits Enter:
1 ~ 9, 0, *, #, Pause (press
line key 1 to enter a
pause)
Set the gain table to be used
(1 ~ 500). If an extension dials
ARS/F-Route number;
The Extension Dial Gain Table
assigned in Program 44-05 is
activated.
The Extension Dial Gain Table
follows Outgoing transmit and
Outgoing receive settings.
If the incoming call is transferred
to another line using ARS/
F-Route; the Tandem Gain Table
assigned in Program 44-05 is
activated.
The Tandem Gain Table follows
the Incoming transmit and
Incoming receive settings for
incoming line, and Outgoing
transmit and Outgoing receive
settings for the outgoing line.
For ARS/F-Route calls, the
CODEC gains defined in
Program 14-01-02 and Program
14-01-03 are not activated.
Time Number: 01 ~ 20
Start Time = 0000 ~ 2359
End Time = 0000 ~ 2359
Mode: 1 ~ 8
1283
Default
0
0
0
No Setting
1 ~ 63
(-15.5 ~
+15.5dB)
(default = 32)
1 ~ 63
(-15.5 ~
+15.5dB)
(default = 32)
1 ~ 63
(-15.5 ~
+15.5dB)
(default = 32)
1 ~ 63
(-15.5 ~
+15.5dB)
(default = 32)
All Schedule
Patterns: 0:00 –
0:00, Mode 1

Advertisement

Table of Contents
loading

Table of Contents