NEC UNIVERGE SV9100 Features And Specifications page 1098

Hide thumbs Also See for UNIVERGE SV9100:
Table of Contents

Advertisement

Program
Program Name/Description
Number
20-03-04
System Options for Single Line Telephones
– Dial Sending Start Time for SLT or ARS
Set the time before the first digit is sent out.
When using a third-party external paging
device, set this option to 1. In addition, set
Program 20-03-03 to 1.
20-03-05
System Options for Single Line Telephones
– SLT Operation Mode
Define the Operation Mode for SLT terminals.
20-03-06
System Options for Single Line Telephones
– Headset Ringing Start Time (for SLT)
Define the headset ringing start time. After this
time expires from the time when a single line
telephone is off-hook, the system sets the
single line telephone to headset ringing mode.
20-03-07
System Options for Single Line Telephones
– Trunk Call Dial Forced Sending Start Time
(Forced Dial)
Define the Trunk Call Dial Forced Sending Start
Time.
20-06-01
Class of Service for Extensions
Assign a unique Class of Service for Dual OPX
telephones only when using Continued Dialing.
20-13-13
Class of Service Options (Supplementary
Service) – Continued Dialing (DTMF) Signal
on ICM Call
Turn Off or On an extension user ability to use
Continued Dialing, which allows DTMF signal
sending while talking on extension.
Ring Cycle Setup – Normal Incoming Call on
20-15-01
Trunk
Define the ringing cycle (1 ~ 13) for normal
incoming trunk calls (DIL, ring group, etc.).
Ring Cycle Setup – Incoming Internal Call
20-15-03
Define the ringing cycle (1 ~ 13) for ICM calls.
Ring Cycle Setup – DID/DDI
20-15-05
Define the ringing cycle (1 ~ 13) for DID calls.
DTMF Tone Receiver Setup – Detect Level
80-03-01
Use Items 11 ~ 32 to set the criteria for dial tone
detection for outgoing ARS calls.
Input Data
0 ~ 64800 seconds
0 = Normal Mode
1 = Extended Mode1
2 = Extended Mode2
0 ~ 64800 seconds
0 ~ 64800 seconds
Day Night/Mode: 1 ~ 8
Class of Service of Extensions
(1 ~ 15)
0 = Off
1 = On
Ringing Cycle = 1 ~ 13
Ringing Cycle = 1 ~ 13
Ringing Cycle = 1 ~ 13
0 = 0dBm ~ -25dBm
1 = -5dBm ~ -30dBm
2 = -10dBm ~ -35dBm
3 = -15dBm ~ -40dBm
4 = -20dBm ~ -45dBm
5 = -25dBm ~ -50dBm
6 = -30dBm ~ -55dBm
1098
Default
3
0
5
0
Extension port
101 = Class 15
All other
extension port =
Class 1
COS 1 ~ 15 = 1
2
12
8
Type 1 ~ 5 = 0

Advertisement