Program
Program Name/Description
Number
Service Code Setup (for Service Access) –
11-12-03
Override (Off-Hook Signaling)
Assign the service code used for off-hook
Signaling Override.
Single Digit Service Code Setup – Intercom
11-16-04
Off-Hook Signaling
Assign the one-digit service code used for
off-hook Signaling.
Multiline Telephone Basic Data Setup –
15-02-12
Off-Hook Ringing
Set the telephone off-hook signaling that
occurs when a telephone user receives a
second call while busy on a handset call. To
enable or disable off-hook signaling for an
extension Class of Service, use Program
20-13-06.
15-07-01
Programmable Function Keys
Assign a function key for off-hook Signaling
(code 33).
20-06-01
Class of Service for Extensions
Assign a Class of Service (1 ~ 15) to an
extension.
Input Data
MLT, SLT
*
#
0 ~ 9,
,
Maximum of eight
digits
*
#
0 ~ 9,
,
Maximum of one digit
0 = Muted Off-Hook Ringing
1 = No Off-Hook Ringing
2 = Not Used
3 = Beep in Speaker (SP)
4 = Beep in Handset (HS)
5 = Speaker & Handset Beep
Line Key 1 ~ 48
0 ~ 99 (Normal Function Code
851 by default)
*
*
00 ~
99 (Appearance
Function Code) (Service Code
852 by default)
Day Night/Mode: 1 ~ 8
Class of Service of Extensions
(1 ~ 15)
1218
Default
809
*
5
Extension port
101 = Class 15
All other
extension port =
Class 1