Phone Parameters; Modem Format; Point/User Flag - Bosch D9412G Program Entry Manual

Table of Contents

Advertisement

D9412G/D7412G | Program Entry Guide | 2.0 9000MAIN
2.2

Phone Parameters

The program items in this category describe panel-
wide characteristics for telephone dialing, receiver
format, and supervision.

Modem Format

Default:
Yes
Selection:
Yes or No
Yes
Radionics' Modem IIIa
Communication Format: Reports
identify points as 001 through 247 and
passcode User ID codes as 000 through
249 at the D6500/D6600 Receiver
(unless
programmed Yes; see the
Flag
prompt in this section). When
reporting point events, Radionics'
Modem IIIa
also sends point text to the
D6500/D6600 as programmed in Point
Assignments.
No
BFSK (2300 Hz or 1400 Hz
acknowledgment tone).
Central Station Receiver Format for
Transmission of Reports: Modem format provides
many reporting advantages over the BFSK format.
See the D6500/D6600 Report Directory for more
information about the effect of reporting formats.
Modem Format must be set to Yes when
sending events over a network to a D6600
receiver (NetCom).
0101
If Modem Format is No, be sure to assign
0101
a number to identify Duress Reports in
0101
BFSK Duress Code in this programming
section.
Bosch Security Systems | 10/03 | 47775E
2

Point/User Flag

is
Point/User
2
Communication Format
Point/User Flag
Default:
Yes
Selection:
Yes or No
Yes
The control panel sends a flag with
each report telling the D6500/D6600 to
convert point numbers and User ID
numbers to COMEX format. The
conversions are shown in Table 6 and
Table 7. No matter how the
D6500/D6600 is programmed for
output to the computer system, points
and User ID numbers are converted
when this item is Yes. (See the D6600
Communications Receiver/Gateway
Computer Interface Manual, Appendix C,
Numbered Table and Note 1.)
No
The control panel does not send the
flag. The D6500/D6600 outputs point
numbers as 001 to 247 (rather than 100
to 732) and User ID numbers as 000 to
249 (rather than 000 to F08), as
indicated in Table 6 and Table 7.
This program item determines how point and User
ID numbers are presented at the D6500/D6600
display, printer, and computer RS-232 output.
Modem Format
When
is Yes, the control panel
sends expanded Radionics' Modem IIIa
Communication Format reports to the
D6500/D6600. If your central station data files are
not set up for point and User ID number reporting,
you can use this program item to convert these
numbers to COMEX Reports.
Modem Format
When
is Yes, the control panel
sends expanded Radionics' Modem IIIa
Communication Format Reports to the receiver.
Point/User Flag
affects Radionics' Modem IIIa
Communication Format data as shown in Table 6.
The Bosch Security Systems D6500/D6600 Receiver
adds the leading zero in the User ID number with
Point/User Flag
programmed No.
EN | 12
2
2
2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D7412g

Table of Contents