No Data Is Being Output To The Machine, Or The Machine Will Not Operate Even Though Data Is Being Output; The Computer Shuts Down When Connecting Multiple Machines; The Spindle Does Not Rotate; Ate Even Though Data Is Being Output - Roland DWX-51D User Manual

Hide thumbs Also See for DWX-51D:
Table of Contents

Advertisement

Machine Trouble

No Data is Being Output to the Machine, or the Machine will Not Operate Even Though Data is Being Output

Is the front cover open?
Does VPanel recognize the ma-
chine?
If multiple machines are connected,
is the correct machine selected?
Is operation paused?
Is initialization or a data cancel in
progress?
Is the milling data correct?
Has an error occurred?

The Computer Shuts Down when Connecting Multiple Machines

Are machines with the same ID
connected to the computer at the
same time?

The Spindle Does not Rotate

Is the spindle belt damaged or dis-
connected?
48
4. Troubleshooting
If the front cover is open, the machine will not start
milling even if milling data is being received. Close
all of the covers and press the operation button to
start milling.
Verify that a message other than "Offline ("OFF"
display) is shown on VPanel.
Select the machine to output milling data to on the
VPanel screen.
Operation is paused if the PAUSE LED is lit. When the
machine is paused, milling stops and some opera-
tions are restricted. Quickly pressing the operation
button of the machine will cancel the pause. Press-
ing and holding on the operation button will abort
milling.
Milling data received during initialization or a data
cancel will be cancelled. Make sure to output mill-
ing data after confirming that the machine is in the
standby status.
Check the milling data.
The ERROR LED will flash if an error occurs. A de-
scription of the error is displayed in VPanel.
Connecting more than one machine with the same
ID to a computer at the same time may cause the
computer to shut down. If the computer shuts down,
turn off the power of all connected machines, and
then disconnect the USB cables from the computer.
Restart the computer, and then start VPanel. If VPanel
will not start, reinstall it. After that, configure the set-
tings so that no machines are assigned the same ID.
Refer to "Setup Guide" ("Connecting Multiple Units")
to perform the work.
Check inside the maintenance cover. If the spindle
belt is damaged, replace it.
-
-
-
-
-
-
P. 60
-