Periodic Maintenance
Close the front cover.
3.
Perform automatic correction.
Once automatic correction is complete, remove the detection pin and the automatic correction jig.
To remove the automatic correction jig, turn the screws securing the automatic correction jig about 3times, and then
pull out the automatic correction jig while pushing down on its screw heads. (
step
to
40
3. Maintenance
) Store the detection pin and the automatic correction jig in the storage compartment.
Use a torque driver to alternately tighten the
screws in the two locations little by little.
Failing to alternate between the screws when
tightening them may cause the automatic correction
jig to become tilted.
Show VPanel.
 P. 5"Displaying VPanel"
In the top window of VPanel, select the machine to
operate.
Click the radio button to the left of the name of the machine to
operate.
Click
.
The [Settings] screen will appear.
Click the [Maintenance] tab.
Click [Automatic correction].
Make sure that the work displayed on the screen is
complete.
Click [OK].
Automatic correction starts.
Automatic correction is complete once the screen in the figure is
displayed.
Click [OK].
 P. 39"Attach the automatic correction jig."