Genie GTH-2506 AU.3 Operator's Manual page 53

Table of Contents

Advertisement

Second Edition - Second Printing
Quick Attach Instructions
1. Drive to the place where you will release the
mounted attachment (when possible, a solid
and sheltered site).
2. Disconnect the quick connectors of the attachment
(if any).
3. Rest the attachment flat on the ground.
4. Remove the safety pin placed on attachment
lock pin.
5. Press the Lock/Unlock Enabling Switch and keep
it pressed up to the end of Step 6.
6. Retract the attachment lock cylinder to free the
attachment by simultaneously pressing the
white button on the joystick, the hydraulic quick
coupling lock/unlock button, the function enable
button on the joystick, and shifting the joystick
to the right.
7. Tilt the attachment frame forward and lower the
boom to release the attachment upper lock.
8. Move back with the machine and drive to the new
attachment to be coupled.
9. Hold the frame tilted forward and hook the upper
lock of the new attachment.
Part No.
57.0009.0730
Operating Instructions
10. Retract and raise the attachment a small distance.
It will center automatically on the quick coupling
frame.
11. Extend the attachment lock cylinder and replace
the safety pin previously removed.
12. Re-couple the connectors of the attachment (if
any).
13. Select the correct attachment through the LMS
control panel (see "Load Management System"
section).
GTH-2506 AU.3
March 2018
51

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents