Operating Instructions
Primary home screen (28). Press button next to
icon to return to the primary home screen.
Chassis pitch angle indicator (29). Graphical
display of chassis pitch angle direction.
Chassis pitch angle readout (30). Numerical
display of chassis pitch angle, in degrees.
Negative values indicate the front of the chassis
is lower than the rear, or it's pitched downwards,
whereas a positive value indicates the front of
the chassis is higher than the rear, or it's pitched
upwards.
Boom angle (31). Numerical display of boom
angle in relation to the horizon.
Boom length (32). Distance from the boom pivot
point to attachment coupling pivot point measured
along the boom's longitudinal axis.
Selected attachment (33). See 11.
Outrigger position (34). See 12.
Operator Name (35). Name of logged in operator.
Time/date (36). See 18.
Chassis tilt angle readout (37). Numerical
display of chassis tilt angle, in degrees. A positive
value indicates the machine is tilting to the right a
negative value indicates the machine is tilting to
the left.
Chassis tilt angle indicator (38). Graphical
display of chassis tilt angle direction.
Alarms and warnings (39). Active alarms and
warnings automatically scroll through this window.
A blank window indicates there are no active
alarms or warnings.
48
The LMS override key should be kept by the
site manager or the person responsible for
jobsite safety.
Alarms and Warnings
Alarms and warnings are automatically recorded
into the system's memory. When either of these
events is active, the warning icon is displayed
in the home screen. Alarm events disable boom
functions as if the telehandler is overloaded,
warnings allow the operator to continue using
the machine. Active alarms and warnings can be
viewed in the alarms submenu.
Active alarms list is located in Main_Menu >
Alarms > Active_Alm
Active warnings list is located in Main_Menu >
Alarms > Active_Warn
Each event recorded stores the following
information:
Date and time the event occurred
Error code number
Event description
Duration of the event.
A malfunctioning machine must never be used. If
malfunctions are discovered, the machine must
be tagged and removed from service. Call Genie
Technical Support for assistance.