Operating Instructions
Load Management System
Override Key Switch
This switch allows the override of the LMS in order
to recover the machine:
when it is stuck after the load limiting system
has triggered;
in case of main machine failures requesting the
unlock of all the machine movements;
In order to prevent any misuse of this device (ie
working outside the load and stability limits of the
machine), the LMS is provided with a timer (calibrated
at 10 seconds) which, after this time is expired,
restores automatically the lock-out functions.
When the LMS override key switch is on, the L8
functional led lights with a solid red light.
The LMS override key switch is active only in the
Job-site mode.
50
Using The Load Charts
The load chart provided in the cabin (see section
"load charts") specify operating limits for stationary
and "pick and carry" operations, they indicate
the maximum allowable load in relation to boom
extension, boom elevation, outrigger position, and the
type of attachment used. The operator is responsible
for referring to and complying with the conditions
described in these charts.
The extension level of the boom can be checked
with the help of the letters (A, B, C, D, E) painted on
the same boom, while the actual boom inclination
degrees are shown by the angle indicator.
Load Management System
Indicator (Christmas Tree) Lights
(if equipped)
This device, fitted outside the cabin, is connected to
the LMS and shows the same LED sequence which
appears on the LMS display.