Genie GTH-2506 AU.3 Operator's Manual page 32

Table of Contents

Advertisement

March 2018
Inspections
Test the Road Transfer Mode
28 Set the steer select switch to road transfer mode.
29 Attempt to: operate the boom
 Result: None of these functions should operate.
Test the Lights
30 Verify that all equipped working and road lights
are functional.
Test the Load Management System
31 Load a known weight of approximately 1000 kg.
32 Raise the boom about 30 cm above the ground.
33 Extend the boom and check if the system enters
the alarm mode once it has reached the distance
as indicated in the load charts for the attachment
fitted to the machine.
 Result: The LMS alarm should sound and boom
movement stop.
Test the Joystick Enabling Function
Switch
34 Operate the joystick without pressing this button.
 Result: the joystick shall not activate any
movement.
30
Test the Emergency Stop Push button
35 Press the Emergency Stop Push button down
during a movement.
 Result: the movements shall stop and engine
should shut down.
Test the Seat Switch
36 Sit on the driver seat.
37 Release parking and service brakes.
38 Place transmission into forward or reverse gear.
39 Lift body weight off the driver seat.
40 Push down lightly on the accelerator pedal.
 Result: the machine should not move.
GTH-2506 AU.3
Second Edition - Second Printing
Part No.
57.0009.0730

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents