5
HEATING-COOLING TEMPERATURE CONTROL MODULE/
AnS/QnAS series
Product
A1S64TCTT-S1
A1S64TCTTBW-S1
A1S64TCRT-S1
A1S64TCRTBW-S1
Heating-cooling
temperature control
module
Temperature control
A1S62TCTT-S2
module
A1S62TCTTBW-S2
A1S62TCRT-S2
A1S62TCRTBW-S2
Model
Model
L60TCTT4
L60TCTT4BW
L60TCRT4
L60TCRT4BW
L60TCTT4
L60TCTT4BW
L60TCRT4
L60TCRT4BW
Transition to L series
Remarks (Restrictions)
1) External wiring: Cable size is changed.
2) Number of slots: Not changed
3) Program: The number of occupied I/O points, I/O signals, and
buffer memory addresses are changed.
4) Performance specifications: Not changed
5) Functional specifications: Changed (Refer to Section 5.3.)
1) External wiring: Cable size is changed.
2) Number of slots: Changed (2 modules occupied, 16 intelligent
points)
3) Program: The number of occupied I/O points, I/O signals, and
buffer memory addresses are changed.
4) Performance specifications: Not changed
5) Functional specifications: Changed (Refer to Section 5.3.)
1) External wiring: Cable size is changed.
2) Number of slots: Not changed
3) Program: The number of occupied I/O points, I/O signals, and
buffer memory addresses are changed.
4) Performance specifications: Not changed
5) Functional specifications: Changed (Refer to Section 5.3.)
1) External wiring: Cable size is changed.
2) Number of slots: Changed (2 modules occupied, 16 intelligent
points)
3) Program: The number of occupied I/O points, I/O signals, and
buffer memory addresses are changed.
4) Performance specifications: Not changed
5) Functional specifications: Changed (Refer to Section 5.3.)
1) External wiring: Cable size is changed.
2) Number of slots: Not changed
3) Program: The number of occupied I/O points, I/O signals, and
buffer memory addresses are changed.
4) Performance specifications: Changed (2 channels/module  4
channels/ module)
5) Functional specifications: Changed (Refer to Section 5.3.)
1) External wiring: Cable size is changed.
2) Number of slots: Changed (2 modules occupied, 16 intelligent
points)
3) Program: The number of occupied I/O points, I/O signals, and
buffer memory addresses are changed.
4) Performance specifications: Changed (2 channels/module  4
channels/ module)
5) Functional specifications: Changed (Refer to Section 5.3.)
1) External wiring: Cable size is changed.
2) Number of slots: Not changed
3) Program: The number of occupied I/O points, I/O signals, and
buffer memory addresses are changed.
4) Performance specifications: Changed (2 channels/module  4
channels/ module)
5) Functional specifications: Changed (Refer to Section 5.3.)
1) External wiring: Cable size is changed.
2) Number of slots: Changed (2 modules occupied, 16 intelligent
points)
3) Program: The number of occupied I/O points, I/O signals, and
buffer memory addresses are changed.
4) Performance specifications: Changed (2 channels/module  4
channels/ module)
5) Functional specifications: Changed (Refer to Section 5.3.)