Setting The Controller - Siemens Sinamics G110M Original Instructions Manual

Distributed converter for simogear geared motors
Hide thumbs Also See for Sinamics G110M:
Table of Contents

Advertisement

Functions
8.9 Application-specific functions
8.9.6.2

Setting the controller

Simplified representation of the technology controller
The technology controller is implemented as a PID controller (controller with proportional,
integral, and derivative action).
The inverter uses the start value when all the following conditions are simultaneously satisfied:
The technology controller supplies the main setpoint (p2251 = 0).
The ramp-function generator output of the technology controller has not yet reached the start value.
Figure 8-39
Simplified representation of the technology controller
The settings required as a minimum are marked in gray in the function diagram: Interconnect
setpoint and actual values with signals of your choice, set the ramp-function generator and
controller parameters K
You will find information on the following PID controller topics in the Internet at: Manuals for
your converter (Page 334)
● Setpoint value specification: Analog value or fixed setpoint
● Setpoint channel: Scaling, ramp-function generator and filter
● Actual value channel: Filter, limiting and signal processing
● PID controller Principle of operation of the D component, inhibiting the I component and
the control sense
● Enable, limiting the controller output and fault response
234
, T
and T
.
P
I
d
Operating Instructions, 04/2015, FW V4.7.3, A5E31298649B AD
SINAMICS G110M Operating Instructions

Advertisement

Table of Contents
loading

Table of Contents