3 Operation and Configuration
3-7-4

Initial Counter Value

Every Counter has device variables for CJ-series Unit (for setting) (double word) for the initial Counter
Values. The settings for these variables are transferred from the CPU Unit to this unit when the Unit
restarts or the Controller is reset, including when the power is turned ON. The initial Counter Values
overwrite the Counter Values and become the new Counter Values.
Name of device variable
for CJ-series Unit
*_Ch1_InitLinCtCfg
*_Ch2_InitLinCtCfg
*_Ch1_InitRingCtCfg
*_Ch2_InitRingCtCfg
3-44
Type
Name
DINT
Initial Counter Value
UDINT
Initial Counter Value
CJ-series High-speed Counter Units Operation Manual for NJ-series CPU Unit(W492)
Function
• Sets the initial Counter Value after unit
setting data is transferred.
• Used for Simple Counter or Linear
Counter.
• Data range:
−2,147,483,648 to 2,147,483,647.
• Unit: Pulses
• Sets the initial Counter Value after unit
setting data transferred.
• Used for Circular Counter.
• Data range:
0 to 4,294,967,295
• Unit: Pulses